We read the ENA Type Test Register at 11:29 UTC on 10 November 2026: 157 entries, 132 Compliant from 30 suppliers, and 25 Non-compliant. Three days earlier it held 150 entries and 130 Compliant from 29 suppliers. Two of the new Compliant lines are worth a buyer’s attention — a third kit from APsystems, and a first from a supplier that has never appeared on the register before.
APsystems’ third Compliant entry
ALTEN/22029/V1 is listed Compliant for “Premium Set Dual-1010W-Full black”, submitted by Altenergy Power System Inc. — the company that sells as APsystems. It joins the two entries we have been citing since September.
| Reference | Model | Published | Capacity |
|---|---|---|---|
| ALTEN/22029/V1 | Premium Set Dual-1010W-Full black | 26 October 2026 | 0.799 kW |
| ALTEN/21303/V1 | Premium Set Dual-1020W-Full black | 2 September 2026 | 0.799 kW |
| ALTEN/21341/V1/A1 | Premium Set Single-510W-Full black | 7 September 2026 | 0.5 kW |
1,010 W in the name, 0.799 kW on the register
The two two-panel sets differ by 10 W in their names and not at all in the figure the register records: both are 0.799 kW. That is not a contradiction, and it is the most useful thing on this page. The wattage in a kit’s name is almost always its panels added together — the DC side. The register’s capacity field is the AC side: what the microinverter is permitted to put into the house. Our guide to why plug-in solar output is limited sets out why that ceiling sits where it does.
So the practical difference between the 1,010 W and the 1,020 W set is not how much electricity reaches your sockets on a bright afternoon. It is in the panels, and the register does not describe them beyond the model name. Nor does a listing say whether either set is on sale in the UK — that is a question for the shop, not the register.
Dated 26 October, and not on the register on 7 November
The new entry carries a published date of 26 October 2026, a fortnight before it reached the data we read. Our 7 November snapshot does not contain it, and nor does any snapshot we have taken since 21 September. The published date records when the submission was dated, not when you could find it.
That is worth knowing if you are checking a kit before you buy. A reference that is not on the register today may appear next week carrying a date from last month. Absence is not refusal, and it is not evidence that a kit was rejected — it is a reason to look again.
A first entry for LumeGret
LUMEG/22127/V1 — “LumeGret M800”, 0.8 kW, published 30 October 2026 — is listed Compliant. It is the first entry for LumeGret Energy Technology (Suzhou) Co., Ltd and makes it the 30th supplier with at least one Compliant kit. We have not found the brand on sale in the UK, and the register is not the place to look for that: a listing is a type-test listing, nothing more. It is not a recommendation, ours or anyone’s, and it does not mean a product has reached British shelves.
One kit points at someone else’s reference
Cody Earth Solutions is back on the register, and the way its entry is written makes a point worth repeating. CODYE/22054/V1 — “The Cody Plug in Solar 1280 Kit”, published 27 October, recorded at 0.799 kW — is listed Non-compliant, and the register’s note against it reads: The Microinverter is certified by ENA at ALTEN/21303/V1 and ALTEN/12127
. The first of those is APsystems’ 1,020 W set in the table above. The second matches no entry in the register data we read.
A compliant microinverter inside a kit does not make the kit compliant. The status belongs to the combination that was assessed — panels, inverter, mounting — and it is recorded against that combination’s own reference. Plug Energy’s three new lines, all published 2 November and all Non-compliant, name a Hoymiles HMS-800-2WB with JA Solar panels in the same way. The check that works is the one in our product compliance checklist: find the kit’s own reference and read the status on it.
Cody’s own history is the other half of the lesson. It held CODYE/20923/V1 from 30 September, that entry was gone by 7 November, and the company reappeared on 10 November under a different reference for a differently named kit. It is the fifth reference we have recorded since the start of October that left the register and came back at a later amendment.
Two listings we named have gone
AOROE/21759/V1, Aoro Energy’s “M1-800-E”, and INSTA/21195/V1/A2, InstaGroup’s “INS-PPG2-800”, have both been removed. We named the first when the register passed 126 Compliant kits and the second when Levocell joined and three entries were removed. Both were Non-compliant throughout, so nothing anyone could buy on the strength of them has changed.
The rest of the movement since 7 November is all Non-compliant: two more Polyshine Solar flexible kits (870 W, published 27 October), which takes Polyshine to four entries and none Compliant; the three Plug Energy kits above; and TSUNE/21521/V1/A2, a “TSOL-MS2000(800)” from TSUNESS — its first Non-compliant line, alongside five Compliant references covering four models. Our register guide lists the Compliant entries and only counts the rest, because a status can change in either direction.
What it means for UK buyers
Match the reference, not the model name. Two of APsystems’ three entries have nearly the same name and the same registered capacity; one kit on this list says its inverter is certified under a reference belonging to another company. The only check that settles anything is the status printed against the kit’s own reference on the day you look.
Read a wattage in a product name as panels, not output. A “1,010 W” or “1,280 W” kit is describing its panels. What the inverter may feed into your home is the figure in the register’s capacity column, and for every two-panel kit here that is 0.799 or 0.8 kW.
Check again before you conclude anything. Entries arrive carrying earlier dates, and references leave and return. Five have done so since the start of October.
Nothing here changes what you may plug in. The rules are the same as last week; what changed is the list of kits that have been through the type test. The current position is set out in is plug-in solar legal in the UK, and the Compliant list, with the date we last read it, is in the register guide.
Update, 13 November 2026
Three of the Non-compliant lines this post describes have already gone. CODYE/22054/V1 — the Cody kit whose note pointed at APsystems’ reference — all four Polyshine Solar entries, and TSUNESS’s TSUNE/21521/V1/A2 were no longer on the register when we read it on 13 November 2026. That is the pattern this post describes running at full speed: Cody’s returned listing lasted three days. APsystems’ three Compliant entries are unchanged. The 13 November read, with thirteen new Compliant lines, is here.