Plug-in solar has been legal to use in Great Britain since 27 August 2026. On 17 September, New Scientist reported that the Institution of Engineering and Technology (IET), the engineering body behind the IET Wiring Regulations (BS 7671), believes two safety concerns it raised with the government were not dealt with first. Mark Coles, its head of technical regulations, told the magazine the change had been “rushed”.
The two concerns
RCDs. A residual current device in your consumer unit cuts the power within milliseconds when it senses current leaking to earth. The IET says most RCDs in UK homes were not designed for circuits where power can flow in both directions, and could malfunction with plug-in solar. A related worry, raised in the consultation, is that DC current leaking from electronic equipment can make older RCDs less sensitive.
Islanding. When the grid goes down, a plug-in kit must switch itself off so it cannot keep a circuit live. The IET’s concern is that several kits in one area could, in theory, fool each other into thinking the grid is still on, putting people repairing the network at risk. See anti-islanding explained.
What the government says
A DESNZ spokesperson told New Scientist that an independent contractor had fully tested plug-in solar devices on UK house wiring and found them safe, and that tests with older household protective devices found no evidence their protection was affected. Coles replied that those tests used kits bought outside the UK, because none was legal here at the time, and new RCDs.
The government’s consultation response of July 2026 deals with the RCD point. It says DC leakage that can reduce the effectiveness of older, mostly type AC, RCDs is not unique to plug-in solar, because many modern power supplies leak small amounts of DC. In response it amended the Interim Product Specification so that a kit’s smooth DC leakage into the mains must not exceed 5 mA, and it is running further tests on older type AC protective devices, after which that limit will be reviewed. The specification also sets anti-islanding requirements every compliant kit must meet.
The specification is described as interim: the government says longer-term changes to standards, including the wiring regulations, are being considered separately. The disagreement is about whether the interim rules go far enough in the meantime.
What it means for you
- Buy a kit listed as compliant on the ENA Type Test Register. Compliant kits have been assessed against the specification, including the DC leakage and anti-islanding rules. See every kit the register lists.
- Test your RCD with the kit running. The specification tells manufacturers to instruct you to press the test button on your RCD or RCBO while the kit is producing power, and to call an electrician if it does not trip straight away.
- Look at your fuse box first. If it has old rewireable fuses, is not labelled, or you do not know its condition, the specification says to have it inspected by a qualified electrician before you install a kit.
- Plug straight into a wall socket, never an extension lead, multi-way adaptor or RCD adaptor.
For the detail on RCD types and DC leakage, read RCDs, DC leakage and plug-in solar.