New consumer safety guidance on plug-in solar

The Electrical Safety Roundtable has published a five-page guide for consumers buying plug-in solar. Most of it confirms what the rules already require. The useful parts are the two it explains with diagrams: how a kit can overload a circuit, and which RCDs cope with power flowing both ways.

Written and edited by Christopher Panteli

·

Christopher is the founder and editor of MyPlugInSolar. He oversees the site’s research standards, data tools and editorial process. He is not an electrician or solar installer, and specialist technical claims are sourced from official documentation or reviewed by appropriately qualified professionals.

At a glance

  • “Plug-in Solar Devices: Guidance for consumers”, five pages, reference ID8216 201026 V1, so dated 20 October 2026. Reported by Installer Online on 5 November. We read the PDF first-hand on 7 November.
  • It explains why it is one device per household: “The IPS permits one device to be installed per final circuit but this is superceded currently by network operator requirements that only permit one device per household.”
  • On storage: “Plug-in battery storage systems, although available, are NOT permitted at the present time.”
  • New material for most readers: a worked overload example — a kit adds its current downstream of your consumer unit, so “32 A (grid) + 3.5 A (800 W) = 35.5 A” on a cable rated 32 A — and a page on RCD types and bidirectional power flow.
  • It recommends an electrical assessment before installing, suggesting an EICR at “normally no more than ten years for an owner-occupied home and five years for a rented home”. That is industry advice, not a legal requirement.

The Electrical Safety Roundtable has published a five-page guide for people buying plug-in solar. Its reference code, ID8216 201026 V1, dates it 20 October 2026; Installer Online reported it on 5 November. We read the document itself on 7 November rather than working from the write-up.

Most of it restates what the rules already require, which is reassuring rather than newsworthy. Two pages do something we have not seen aimed at consumers before: they explain, with diagrams, the two ways an ordinary house can be the wrong house for a plug-in kit.

Why it is one device per household

This is the clearest explanation of a rule we get asked about a lot:

The IPS permits one device to be installed per final circuit but this is superceded currently by network operator requirements that only permit one device per household.

So the product specification and the connection rules say different things, and the stricter one wins. That is worth knowing if you have read the specification and wondered why everyone says one per home — see how to register plug-in solar.

On storage it is blunt: Plug-in battery storage systems, although available, are NOT permitted at the present time. The capitals are the ESR’s. It also sets out what a compliant device contains — one to four panels up to 2,000 W combined, a grid-following inverter with a Maximum AC output: 800 VA, factory-assembled cabling, and A non-rewireable moulded BS 1363-1 plug (Maximum fuse 5 A) — and that A compliant device should be marked and accompanied by a statement stating that it complies with the IPS. Our compliance checklist covers the same ground, and the legal position cites the primary sources.

The overload example is the part worth reading

A plug-in kit does not just add generation; it adds current at a point your consumer unit cannot see. The ESR puts it plainly: A plug-in solar device will add to the current supplied by the grid via the protective device in your consumer unit. Its first diagram works the sum through on a ring final circuit: the grid contributes 32 A through the breaker, the kit adds 3.5 A downstream of it, and the cable carries both — 32 A (grid) + 3.5 A (800 W) = 35.5 A against a cable rated at 32 A, so Total supply (35.5 A) exceeds the cable rating (32 A). The breaker never sees the excess, because the solar is connected on the far side of it.

The ESR is careful that this is a risk in badly designed or faulty circuits rather than a defect in every home, and says a dedicated circuit would be ideal. But the framing is the useful bit: It is likely that your electrical installation will not have been designed to accommodate a source of generation such as plug-in solar so there may be components within it that may not be suitable and could be damaged.

And a second industry body on RCDs

The last page is about protective devices, and it says what we have been saying since September on the strength of Electrical Safety First. A Type AC RCD Detects AC residual fault currents only and is Not suitable for many modern solar inverters (which can produce DC fault currents); a unidirectional RCD May be damaged or not operate correctly with reverse power flow, because connecting plug-in solar means power may flow both ways across the device.

Two named industry bodies now give the same advice, which is why our RCD guide and the note on checking yours put it near the top of what to do before you buy. The ESR adds that these devices should be checked before installation as part of an assessment of suitability which may include an EICR.

Where it asks more of you than the rules do

Three things in the guide go beyond what the law requires, and the guide is clear that they are recommendations.

  • An electrician before you install. We would strongly recommend that you appoint a qualified and competent electrician to perform the necessary checks on your electrical system before installing. Plug-in solar is legal to install yourself and no electrician is required — see whether you need an electrician. This is safety advice from an industry body, not a legal duty.
  • An assessment, and possibly an EICR. It is recommended that, at a minimum, a specific assessment of your electrical system is undertaken to check whether it is suitable for plug-in solar. On intervals: normally no more than ten years for an owner-occupied home and five years for a rented home. Those intervals are the standard ones for any home, not a plug-in solar rule.
  • Above 960 W of panels. The duty here falls on the maker, not you: for systems with panels rated above 960 W, the manufacturers instructions need to include a recommendation for a professional assessment of the existing electrical installation. Most two-panel kits sold here are above that figure.

Nick Hayler, chair of the Electrical Safety in the Home group, told Installer Online: We support innovation that can help households embrace renewable energy and reduce their bills, but it has to be done safely. Consumers should follow the guidance and use a competent and qualified person to help ensure their plug-in solar device is suitable and installed correctly.

What it means for UK buyers

Nothing you must do differently. The guidance does not change any rule. If you have followed our checklist — a Compliant register entry for your exact kit, one device, 800 VA, notified to your network operator — you are where this document wants you to be.

Check the socket you plan to use, not just the kit. Ideally, the device should be connected to a nearby suitably located and protected external socket-outlet. And: Extension leads, splitters, travel adaptors, and RCD adaptors should never be used and the device should not be connected to a circuit supplying fixed equipment like cookers or lighting. That last clause rules out more kitchen and utility-room sockets than people expect.

The permissions list is longer than most buyers assume. You should call your insurer before purchasing a plug-in solar device to check whether it will affect your cover. Flat owners must check the building owner’s requirements, with Building Safety Regulator duties where equipment is fixed to balconies, external walls or shared parts; renters and social tenants will need to seek permission from your landlord. See landlord and freeholder permission and home insurance.

Timber balconies: the guide agrees with the specification. installation is prohibited for timber balconies and some cladding systems. That is not new — the government’s product specification already says it, and our balcony guide carries it alongside the separate point that in England a wooden balcony or timber-clad wall is not permitted development.

Notify within 28 days. Following the installation, you will also need to notify the Distribution Network Operator (DNO) within 28 days. Same deadline we give, and the same one most people forget.

Sources

  1. 1. Plug-in Solar Devices: Guidance for consumers (ID8216 201026 V1), read 7 November 2026 — Electrical Safety Roundtable, 20 October 2026
  2. 2. New guidance on plug-in solar — Installer Online, 5 November 2026
  3. 3. Plug-in Solar Device Interim Product Specification, version 2.0 — Department for Energy Security and Net Zero, 16 July 2026

Where the UK rules stand

Plug-in solar has been legal to use in Great Britain since 27 August 2026, when SI 2026/848 came into force alongside Ofgem-approved changes to the G98 connection code — provided the kit is listed as compliant on the ENA Type Test Register. Northern Ireland is not covered. See the current legal status and our editorial policy.

Back to all updates