The Electrical Safety Roundtable has published a five-page guide for people buying plug-in solar. Its reference code, ID8216 201026 V1, dates it 20 October 2026; Installer Online reported it on 5 November. We read the document itself on 7 November rather than working from the write-up.
Most of it restates what the rules already require, which is reassuring rather than newsworthy. Two pages do something we have not seen aimed at consumers before: they explain, with diagrams, the two ways an ordinary house can be the wrong house for a plug-in kit.
Why it is one device per household
This is the clearest explanation of a rule we get asked about a lot:
The IPS permits one device to be installed per final circuit but this is superceded currently by network operator requirements that only permit one device per household.
So the product specification and the connection rules say different things, and the stricter one wins. That is worth knowing if you have read the specification and wondered why everyone says one per home — see how to register plug-in solar.
On storage it is blunt: Plug-in battery storage systems, although available, are NOT permitted at the present time.
The capitals are the ESR’s. It also sets out what a compliant device contains — one to four panels up to 2,000 W combined, a grid-following inverter with a Maximum AC output: 800 VA
, factory-assembled cabling, and A non-rewireable moulded BS 1363-1 plug (Maximum fuse 5 A)
— and that A compliant device should be marked and accompanied by a statement stating that it complies with the IPS.
Our compliance checklist covers the same ground, and the legal position cites the primary sources.
The overload example is the part worth reading
A plug-in kit does not just add generation; it adds current at a point your consumer unit cannot see. The ESR puts it plainly: A plug-in solar device will add to the current supplied by the grid via the protective device in your consumer unit.
Its first diagram works the sum through on a ring final circuit: the grid contributes 32 A through the breaker, the kit adds 3.5 A downstream of it, and the cable carries both — 32 A (grid) + 3.5 A (800 W) = 35.5 A
against a cable rated at 32 A, so Total supply (35.5 A) exceeds the cable rating (32 A)
. The breaker never sees the excess, because the solar is connected on the far side of it.
The ESR is careful that this is a risk in badly designed or faulty circuits rather than a defect in every home, and says a dedicated circuit would be ideal. But the framing is the useful bit: It is likely that your electrical installation will not have been designed to accommodate a source of generation such as plug-in solar so there may be components within it that may not be suitable and could be damaged.
And a second industry body on RCDs
The last page is about protective devices, and it says what we have been saying since September on the strength of Electrical Safety First. A Type AC RCD Detects AC residual fault currents only
and is Not suitable for many modern solar inverters (which can produce DC fault currents)
; a unidirectional RCD May be damaged or not operate correctly with reverse power flow
, because connecting plug-in solar means power may flow both ways across the device.
Two named industry bodies now give the same advice, which is why our RCD guide and the note on checking yours put it near the top of what to do before you buy. The ESR adds that these devices should be checked before installation as part of an assessment of suitability which may include an EICR.
Where it asks more of you than the rules do
Three things in the guide go beyond what the law requires, and the guide is clear that they are recommendations.
- An electrician before you install.
We would strongly recommend that you appoint a qualified and competent electrician to perform the necessary checks on your electrical system
before installing. Plug-in solar is legal to install yourself and no electrician is required — see whether you need an electrician. This is safety advice from an industry body, not a legal duty. - An assessment, and possibly an EICR.
It is recommended that, at a minimum, a specific assessment of your electrical system is undertaken to check whether it is suitable for plug-in solar.
On intervals:normally no more than ten years for an owner-occupied home and five years for a rented home
. Those intervals are the standard ones for any home, not a plug-in solar rule. - Above 960 W of panels. The duty here falls on the maker, not you: for systems with panels rated above 960 W,
the manufacturers instructions need to include a recommendation for a professional assessment of the existing electrical installation.
Most two-panel kits sold here are above that figure.
Nick Hayler, chair of the Electrical Safety in the Home group, told Installer Online: We support innovation that can help households embrace renewable energy and reduce their bills, but it has to be done safely. Consumers should follow the guidance and use a competent and qualified person to help ensure their plug-in solar device is suitable and installed correctly.
What it means for UK buyers
Nothing you must do differently. The guidance does not change any rule. If you have followed our checklist — a Compliant register entry for your exact kit, one device, 800 VA, notified to your network operator — you are where this document wants you to be.
Check the socket you plan to use, not just the kit. Ideally, the device should be connected to a nearby suitably located and protected external socket-outlet.
And: Extension leads, splitters, travel adaptors, and RCD adaptors should never be used and the device should not be connected to a circuit supplying fixed equipment like cookers or lighting.
That last clause rules out more kitchen and utility-room sockets than people expect.
The permissions list is longer than most buyers assume. You should call your insurer before purchasing a plug-in solar device to check whether it will affect your cover.
Flat owners must check the building owner’s requirements, with Building Safety Regulator duties where equipment is fixed to balconies, external walls or shared parts; renters and social tenants will need to seek permission from your landlord
. See landlord and freeholder permission and home insurance.
Timber balconies: the guide agrees with the specification. installation is prohibited for timber balconies and some cladding systems.
That is not new — the government’s product specification already says it, and our balcony guide carries it alongside the separate point that in England a wooden balcony or timber-clad wall is not permitted development.
Notify within 28 days. Following the installation, you will also need to notify the Distribution Network Operator (DNO) within 28 days.
Same deadline we give, and the same one most people forget.