Panels & output
Plug-in solar output across the UK by region
The same plug-in kit does not generate the same amount everywhere in the UK — but the gap between the sunniest and dullest parts of the country is smaller than most people assume, and smaller than the gap between a good mounting position and a poor one.This guide puts modelled figures for ten cities side by side, using the same source and settings as the calculator.
Written and edited by Christopher Panteli
Christopher is the founder and editor of MyPlugInSolar. He oversees the site’s research standards, data tools and editorial process. He is not an electrician or solar installer, and specialist technical claims are sourced from official documentation or reviewed by appropriately qualified professionals.
What the same kit makes, city by city
The figures below come from PVGIS, the European Commission’s solar model, using the same settings our calculator starts with: a 0.8 kWp array facing south, tilted at 35°, mounted on a building, with 14% system losses and no shading. Only the location changes from row to row, so every difference you see is geography.
| City | Where | Yearly output |
|---|---|---|
| Penzance | West Cornwall | 853 kWh |
| Cardiff | Wales | 798 kWh |
| London | Greater London | 795 kWh |
| Birmingham | West Midlands | 754 kWh |
| Newcastle upon Tyne | North East England | 736 kWh |
| Belfast | Northern Ireland | 714 kWh |
| Aberdeen | North East Scotland | 701 kWh |
| Manchester | North West England | 689 kWh |
| Glasgow | West Central Scotland | 664 kWh |
| Inverness | Highlands | 628 kWh |
Each row uses the centroid of a central postcode district — TR18 for Penzance, EC1A for London, G1 for Glasgow and so on. These are modelled long-term averages, not a forecast: a single year can land either side of the average, and a real wall, balcony or roof will differ from a clear south-facing reference plane.
Latitude is not the whole story
The spread is real but narrower than most people expect. West Cornwall makes about 36% more than the Highlands, and the Highlands still get roughly three-quarters of the Cornish figure. Across the middle of the country the band is tighter still: Cardiff, London and Birmingham sit within about 6% of each other.
More useful is that the ranking does not follow latitude. Newcastle, about 100 miles north of Manchester, is modelled about 7% higher. Aberdeen, nearly 90 miles north of Glasgow, beats both Glasgow and Manchester. In the model the drier eastern side of the country does better than the cloudier west at the same latitude, so “further north” and “less sun” are not the same thing.
Orientation and shading move more than your postcode
Where you live sets the ceiling. How you mount the panels decides how much of that ceiling you actually reach — and those choices are bigger levers than the map. On the calculator’s own factors:
- Facing east or west instead of south costs about 15% — much the same as moving a south-facing kit from London to Glasgow.
- Moderate shading across part of the day costs about 20%, close to the entire gap between west Cornwall and Glasgow.
- Facing north halves output. No move within the UK comes anywhere near that.
Put those together and a clear, south-facing kit in Glasgow (664 kWh in the table) comfortably beats an east-facing, moderately shaded one in London, which the same factors put near 540 kWh. Location is the one factor you cannot change, and it is rarely the one that decides the outcome. See what affects plug-in solar output, direction and angle and shading.
The 800W cap flattens the difference
A plug-in system is limited by its inverter, not its panel area. Kits are built around an 800 W inverter, and that inverter sets the ceiling on what can flow into the house at any one moment. Adding panel capacity past that point does not raise the peak: it brings the system up to the cap earlier in the morning, holds it there longer, and pushes useful output further into the shoulder months. Why plug-in solar output is limited covers the cap itself.
That shapes this comparison twice over. A sunnier location spends more hours sitting at the cap rather than generating a higher peak, which is part of why the regional spread is narrower than raw sunshine totals suggest. And in a cloudier location a slightly larger array is a sensible way to claw some of the gap back, because it reaches useful output sooner on dull days — see how much an 800W system generates.
What the spread means for savings and payback
Generation is not saving. What a kit is worth turns on how much of its output you use while it is being produced — self-consumption — and on your unit rate, which is why the pounds belong in the calculator rather than in a table.
The shape of the difference is straightforward, though. The 225 kWh a year between Penzance and Inverness is about 160 kWh of electricity you would actually use, on the calculator’s middling daytime-use assumption. Hold the kit, its cost and that assumption steady and payback stretches by roughly a third going from the far south-west to the Highlands — not by a factor of two. Payback period works that through.
Northern Ireland and Scotland are not special cases here: Belfast’s 714 kWh sits mid-table, above Manchester — see plug-in solar in Northern Ireland. The season is the bigger swing for everyone. December is the weakest month in every city above, and the gap between December and June in one place is several times the gap between the best and worst places — see plug-in solar in winter.
Use your own postcode
Frequently asked questions
- Does plug-in solar work in Scotland?
- Yes. On PVGIS figures checked in October 2026, a south-facing 800W array is modelled at about 664 kWh a year in Glasgow and 628 kWh in Inverness, against 853 kWh in west Cornwall — roughly three-quarters as much. Aberdeen, at 701 kWh, is modelled above Manchester.
- Which part of the UK gets the most solar output?
- The south-west coast. Penzance tops this ten-city table at about 853 kWh a year for a south-facing 800W array, ahead of Cardiff and London at around 795 to 800 kWh.
- Is plug-in solar worth it in the north of England?
- Geography is less of an obstacle than it is assumed to be. Newcastle is modelled at 736 kWh a year, about 7% above Manchester despite being roughly 100 miles further north. Whether a kit is worth it turns on its cost, your unit rate and how much electricity you use during the day, so run your own postcode through the calculator.
- Will my own kit really generate these amounts?
- Treat them as modelled long-term averages for a clear, unshaded, south-facing array at 35 degrees, not a prediction. Shading, a different orientation, a shallower tilt and ordinary year-to-year weather all move the figure, usually downward.
Sources
- 1. PVGIS Photovoltaic Geographical Information System (PVcalc v5.2) — European Commission, Joint Research Centre
- 2. Postcodes.io outcode centroids — Postcodes.io
Estimate your solar potential
See how much electricity a small system could generate at your postcode, and the indicative bill saving.